Where we work, and why only here

Six markets,
read properly

Two in the Gulf, two in North Africa and the eastern Mediterranean, two further south. We went deep on six rather than shallow on forty, because the value in this work is knowing what a regulator actually published this year — and that does not scale to a list of countries on a map.

WHAT YOU HOLD WHERE IT POINTS CE or FDA UKCA only Nothing yet not on the EDE list United Arab Emirates certificate is in the file Egypt names UKCA in its own rules Your own market first
The mark you carry decides the order, and it decides it the opposite way round from what most people assume.
6markets covered, chosen rather than listed
12pages, devices and medicines, each traced and dated
35–45working days, the two published review clocks
Oppositepartner structures demanded by the two Gulf markets
Side by side

The comparison most providers will not publish

Because it shows that the two most obvious markets to enter together demand structurally opposite arrangements — and that a European certificate is worth a great deal in one and nothing at all in the other.

Market Who may apply Local partners required Does an existing approval help Official review Authorisation fee
Saudi Arabia SFDA · verified Aug 2026 A licensed authorised representative established in the Kingdom One per class or general group — the representative confirms to the regulator that no other holds it No. The reliance route closed in 2020 — one dossier route for everyone 35 working days SAR 15,000–23,000
by class
United Arab Emirates EDE · verified Aug 2026 A licensed marketing office or medical warehouse At least two importers, plus one or more distributors Yes — a conformity certificate is part of the file: EC, 510(k) or PMA 45 working days AED 5,000
plus AED 100
Egypt EDA · verified Sep 2026 An Egyptian importing company, local facility or scientific office One applicant holds it — and EDA publishes a procedure for transferring it Yes — and it is the one market here that names UKCA in its own instrument 20 working days
7 on the fast track
Not published
no device fee schedule
Türkiye TİTCK · verified Sep 2026 Any manufacturer, through an authorised representative — which may sit in Türkiye or in the EU Representative mandatory but need not be local; the importer and the seller must be Turkish CE only. UKCA appears nowhere in the law, and UK certificates were dropped from the system at the end of 2020 Not published
no evaluation period
₺335
per product registration
Nigeria NAFDAC · verified Sep 2026 A Nigerian-incorporated local agent holding your power of attorney — required by guideline, not by the gazetted regulation One agent. The certificate may not be transferred without the Agency's approval, and no procedure for obtaining it is published No. UKCA recognition was promised in a 2024 partnership that disclaims legal effect — and no Nigerian instrument names any foreign mark 120 working days
90 in the service charter
US$750
per imported device
South Africa SAHPRA · verified Sep 2026 A natural person resident in South Africa — the licence is issued in that individual's name One representative. There is no product registration at all: the scheme in the 2016 regulations has never been called up CE yes, UKCA no. Six recognised jurisdictions for devices, and the UK is absent — though the MHRA is on the separate medicines list 90 working days
target, for 8 files in 10
R26,200
manufacturer licence

All six rows are traced to the regulators' own publications and dated. Egypt's was corrected in September 2026 — we had previously reported the registration as non-transferable on the strength of secondary sources, and the regulator publishes a transfer procedure. Where a regulator publishes nothing, the cell says so rather than borrowing a number. Put your own device through the fees →

What the table is telling you

The Gulf is not one market

Saudi Arabia requires exclusivity. The UAE prohibits it.

The Saudi regulator expects your representative to confirm that no other representative holds the same class of your devices. UAE statute requires the holder of the marketing right to appoint at least two licensed importers for the same product, and the regulator activated that mechanism in February 2026 under the banner of breaking the monopoly on medical products.

Both facts are ordinary once you know them. Together they mean that a single regional distributor agreement covering "the GCC" — which is what most manufacturers are offered first — cannot be right for both countries at once. It will either breach the Emirati requirement or fail the Saudi confirmation.

The second row is just as consequential in the opposite direction. If you hold a CE certificate or an FDA clearance, the UAE file is substantially assembled already, while Saudi Arabia will assess your technical documentation from first principles regardless. That single difference usually decides which market goes first — and it is the reverse of what most people assume.

Sequencing

Which market to do first

Almost every manufacturer names its first market before it has the information to choose one. Answer five questions and the panel will give you an order — or tell you that the honest answer is "not yet". Nothing is sent anywhere; this runs in your browser.

Five questions

All twelve pages are verified, so the panel sequences devices or medicines — the answer is different for each.

What do you make?
What marketing authorisation do you already hold?
Where is the finished product manufactured?
What kind of product is it?
How many markets can you service in year one?
What conformity certificate do you hold?
Is a distributor already asking to represent you?
Does your commercial route run through public tenders?
How many markets can you actually service in year one?
Suggested order

Devices or medicines?

The two answers have almost nothing in common.

Everything this panel says is traced to a regulator's own publication on one of the twelve market pages. Where a regulator publishes nothing, it says so instead of guessing.

The reasoning, in full, for devices — these are the questions that actually decide the order, and none of them is about market size. For medicines the questions are different in kind: not what mark you carry, but which authority is named on which list, and what the market will be allowed to pay you. Each medicines page opens with its own.

  1. What conformity certificate do you hold?

    The single strongest determinant of cost and speed.

    A current CE certificate or FDA clearance makes the UAE substantially cheaper and faster, because the certificate is part of the file. UKCA only changes the order rather than closing it: it is not named in the Emirati document list and never appeared on any Saudi list, but Egypt names it outright in a dedicated instrument. For a UKCA-only manufacturer Egypt is the opening, not the afterthought.
  2. Is someone already asking to distribute for you?

    An inbound approach changes the order, but not always in the way you would like.

    If a distributor has approached you, the urgent question is whose name goes on the registration. In markets where the authorisation cannot be transferred, signing before that is settled hands them your market access permanently. This is worth two weeks of assessment before it is worth a signature.
  3. What is your device's risk class?

    It changes the evidence burden more than it changes the fee.

    Higher classes attract additional safety and efficacy requirements and a heavier dossier. If your portfolio spans classes, there is usually a sensible first product that opens the relationship, the licences and the representative — after which the rest of the range is incremental rather than a new project.
  4. Are you selling to public tenders?

    The registration is a precondition, not the objective.

    Tender cycles are annual and unforgiving. If your commercial route runs through public procurement, the timeline works backwards from the tender, and that frequently reorders the markets — a registration that lands two months after the submission window is a year wasted.
  5. How many markets can you actually service?

    The honest constraint, and the one most often ignored.

    Every authorisation brings renewals, variations, vigilance reporting and a local relationship to maintain. Two markets done properly beat five registered and neglected — and a lapsed registration costs more to restore than it did to obtain.
The pages

Published, and in preparation

And now, medicines

The six pages above are medical devices. Below are the same six regulators read for medicines — and for a UK company the answer comes out close to inverted: the MHRA is named in four of the six, where UKCA is named in one. The comparative article is here →

All twelve pages are up — six markets, devices and medicines. Each one traced to the regulator's own publication and dated, and each one carrying a section listing what we could not confirm. Where a regulator publishes nothing, the page says so rather than borrowing a number from somewhere else.

What reading the regulator actually produced. Six markets, and in every one of them what we found contradicted something the industry repeats. Saudi review periods quoted at three to five times the published maximum, and a reliance route still being sold six years after it closed. An Emirati two-importer rule described as a February 2026 law when it has been in statute since January 2025. An Egyptian registration reported as non-transferable — including by us, until we read the guideline and corrected it. Turkish certificates from UK notified bodies deleted from the national system in 2020 rather than quietly ignored. A Nigerian promise to recognise UKCA in a document that disclaims legal effect. And a South African product registration scheme that, ten years after it was gazetted, has never been called up — while providers sell "SAHPRA device registration" anyway.

That is the whole argument for this website, and it is why four of the six pages carry a section listing what we could not confirm.

Standard

What "verified" means on this site

Every figure on a market page is traced to the regulator's own publication, with the document name and version where one exists, and the date we last checked it. Where a regulator does not publish something openly — and several do not — we say so on the page and confirm it with the authority during an assessment, rather than repeating a plausible number from a consultancy blog.

We re-check each page quarterly and after any circular or resolution affecting devices. It is a slower way to build a website. It is the only way to build one a regulatory affairs manager can quote internally without checking it first.

Ask about any of the six

Twelve pages, six markets, devices and medicines. Send us the product and the markets you are weighing, and two weeks later you will have the sequence, the cost and an honest view of the order.